{"id":74,"date":"2021-01-20T13:57:37","date_gmt":"2021-01-20T13:57:37","guid":{"rendered":"https:\/\/measure2d.com\/?page_id=74"},"modified":"2021-12-09T01:22:50","modified_gmt":"2021-12-09T01:22:50","slug":"keyence","status":"publish","type":"page","link":"https:\/\/measure2d.com\/index.php\/keyence\/","title":{"rendered":"KEYENCE"},"content":{"rendered":"<p style=\"font-size: 1em;\"><span style=\"color: #000000;\">The Keyence TM-3000 2D Optical Micrometer Measurement System has the hardware capability of measuring multiple (simultaneously) outer diameters and step measurements of your designated part of interest.<\/span><\/p>\n<p><img loading=\"lazy\" class=\"aligncenter size-full wp-image-79\" src=\"https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/keyence.png\" alt=\"\" width=\"726\" height=\"206\" srcset=\"https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/keyence.png 726w, https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/keyence-320x91.png 320w, https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/keyence-540x153.png 540w\" sizes=\"(max-width: 726px) 100vw, 726px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"font-size: 1em;\"><span style=\"color: #000000;\">The <strong>Measure2D\u00ae<\/strong> Software provides functions that are not available in the standard Keyence TM-H1 software. <\/span><\/p>\n<ul>\n<li style=\"font-size: 1em;\"><span style=\"color: #000000;\">The Software provides the unique ability to manage automatic program switching as well as the ability to measure the part in multiple orientations before providing a PASS or FAIL designation. <\/span><\/li>\n<li style=\"font-size: 1em;\"><span style=\"color: #000000;\">The Software [Export to Excel] function is automatically built into the measurement process (direct support for xlsx format) and the measurement data is automatically saved. The exported dataset format includes date\/time stamp, unique measurement number, Program\/Output Index, measured value, upper\/lower tolerance, and PASS\/FAIL designation.<\/span><\/li>\n<li style=\"font-size: 1em;\"><span style=\"color: #000000;\">Finally, the Software provides a statistical analysis of each measured item (mean, standard deviation, min, max, and CPK).<\/li>\n<\/ul>\n<p><img loading=\"lazy\" class=\"alignright size-medium wp-image-97\" src=\"https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/2021.01.21-Barb-Fitting-from-Keyence-Program-320x256.png\" alt=\"\" width=\"300\" height=\"240\" srcset=\"https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/2021.01.21-Barb-Fitting-from-Keyence-Program-320x256.png 320w, https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/2021.01.21-Barb-Fitting-from-Keyence-Program-1024x820.png 1024w, https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/2021.01.21-Barb-Fitting-from-Keyence-Program-768x615.png 768w, https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/2021.01.21-Barb-Fitting-from-Keyence-Program-540x433.png 540w, https:\/\/measure2d.com\/wp-content\/uploads\/2021\/01\/2021.01.21-Barb-Fitting-from-Keyence-Program.png 1286w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p style=\"font-size: 1em;\"><span style=\"color: #000000;\">Our own company&#8217;s manufacturing team utilizes the <strong>Measure2D\u00ae<\/strong> Software when inspecting\/verifying parts for our <strong>MCerberus\u00ae<\/strong> Hardware monitoring system.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"font-size: 1em;\"><span style=\"color: #000000;\"><strong>NOTE:<\/strong> The use of any and all trademarked names (i.e. Keyence, Excel, and as applicable) are utilized under the &#8220;Fair Use&#8221; and\/or &#8220;Collateral Use&#8221; trademark doctrines. Our Software was developed independently of Keyence and we have no official business relationship w the Keyence Corporation.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Keyence TM-3000 2D Optical Micrometer Measurement System has the hardware capability of measuring multiple (simultaneously) outer diameters and step measurements of your designated part of interest. &nbsp; The Measure2D\u00ae Software provides functions that are not available in the standard Keyence TM-H1 software. The Software provides the unique ability to manage automatic program switching as&#8230; <a class=\"more\" href=\"https:\/\/measure2d.com\/index.php\/keyence\/\">Continue reading &rarr;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/pages\/74"}],"collection":[{"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/comments?post=74"}],"version-history":[{"count":29,"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/pages\/74\/revisions"}],"predecessor-version":[{"id":173,"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/pages\/74\/revisions\/173"}],"wp:attachment":[{"href":"https:\/\/measure2d.com\/index.php\/wp-json\/wp\/v2\/media?parent=74"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}